 +====== 3D Printing Clearance ======
 +
 +{{section>tools:clearance_template&noheader&nofooter}}
 +
 +====== Tool Specific Instruction ======
 +
 +===== Point out the following tool features =====
 +
 +  * Maintenance Tag
 +  * Reset Button
 +  * Power Button
 +  * SD Card Slot
 +  * Nozzle
 +  * Build Plate
 +  * Extruder
 +  * Hot End
 +
 +===== Identify & mitigate common hazards =====
 +
 +  * Detached Print
 +  * Nozzle marring the Build Plate
 +  * Blob of Death
 +  * Fire
 +
 +===== Allowable Materials =====
 +
 +  * Can name 2 or more allowable materials for the 3D printers
 +  * Can name materials that are not allowed on the printers.
 +
 +===== Safe Setup/Operation/Cleanup =====
 + 
 +  * Demonstrate proper inspection and preparation of printer prior to use.
 +  * Demonstrate proper cleaning of build plate prior to use.
 +  * Demonstrate switching filament.
 +  * Demonstrate cleaning nozzle.
 +  * Demonstrate slicing a model with appropriate settings.
 +  * Demonstrate setting bed and nozzle temperature.
 +  * Demonstrate proper determination of first layer height and using live Z adjust.
 +  * Demonstrate proper removal of prints from the build surface
 +  * Demonstrate proper cleanup of the area and tools
 +
 +===== Knowledge and Technique =====
 + 
 +  * Knows appropriate temperature ranges for common materials such as PLA.
 +  * Knows appropriate handling of build sheets and filament spools.
 +  * Knows the parts of the printer that can cause burns.
 +
 +
 +===== Instructor will provide =====
 +
 +  * Information on selecting the appropriate bed for the material being printed
 +  * Information on when to use the enclosure with doors open / closed