member_pages:paul_mazaitis:documentation:mig_maintenance
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| member_pages:paul_mazaitis:documentation:mig_maintenance [2024/09/24 14:27] – [Changing the Wire in the MIG Welder] paul | member_pages:paul_mazaitis:documentation:mig_maintenance [2024/09/25 02:52] (current) – [Assembling the gun.] paul | ||
|---|---|---|---|
| Line 25: | Line 25: | ||
| Do not move cylinders without a cap on the cylinder, securing the valve. | Do not move cylinders without a cap on the cylinder, securing the valve. | ||
| - | ===== Remove | + | ===== Change |
| Close the valve on top of the gas cylinder. | Close the valve on top of the gas cylinder. | ||
| Line 124: | Line 124: | ||
| ===== Servicing the MIG Gun ===== | ===== Servicing the MIG Gun ===== | ||
| + | Before servicing the MIG gun, unplug the welder. | ||
| + | |||
| + | ==== Take apart the gun. ==== | ||
| + | |||
| + | - Loosen the lower locking ring a quarter turn, and then pull it downward off the gun onto the hose. | ||
| + | - Loosen the upper locking ring a quarter turn, and then pull it upward off of the gun and over the nozzle. Put the upper locking right in a safe place. | ||
| + | - Gently pry apart the halves of the gun casing (friction fit). | ||
| + | |||
| + | ==== Maintenance ==== | ||
| + | |||
| + | Inspect the copper stranded cable at the base of the gun for any damage. | ||
| + | |||
| + | ==== Changing the wire sheath. ==== | ||
| + | |||
| + | Use two 1/2" wrenches to loosen the brass sheath assembly. | ||
| + | |||
| + | ==== Assemble the gun. ==== | ||
| + | |||
| + | - Gently but firmly press the halves of the gun casing together (friction fit) | ||
| + | * Make sure the trigger is properly fitted to the casing. | ||
| + | * Make sure the trigger is correctly oriented with the nozzle. | ||
| + | - Slide the lower locking ring up the hose, line up the tabs and slots, pull the ring up onto the gun casing and tighten a quarter turn. | ||
| + | - Slide the upper locking ring down over the nozzle, | ||
member_pages/paul_mazaitis/documentation/mig_maintenance.1727188024.txt.gz · Last modified: by paul